Luxsin X8 Firmware Revision History
1.0.0.29
- Added UAC 1.0 support. (Path: Audio Setting -> UAC Version)
- Added Fahrenheit temperature unit for the temperature VU meter. (Path: General -> Temperature Unit)
- Added support for reordering PEQ profiles.
- Fixed an issue where music playback could stop when renaming a PEQ profile.
- Added a new option for the custom remote-control button: Switch to Previous Output. (Path: General -> Key Setting -> Remote Control)
- Fixed an issue where custom remote-control button settings could not be saved.
- Fixed an issue where the screen timeout did not work when trigger was connected.
- Fixed an issue where the ambient light did not turn on after waking from standby.
- Added exception log saving for troubleshooting. (To use this feature, create a folder named exactly luxsinLog in the root directory of a USB-A flash drive. The folder name is case-sensitive. The USB drive must support USB 2.0 and be formatted as FAT32. Insert the USB drive into the X8/X9 USB-A port. When an issue occurs, logs will be saved in this folder. Please contact our support team and provide the log files so we can analyze and resolve the issue more efficiently.
1.0.0.28
- Fixed the audio popping issue during the Windows speaker test.
- Added front panel ambient lighting color adjustment. (Visible through the transparent top cover for users with the V&R Kit installed.)
1.0.0.27
- Set the redesigned Web UI as the default web interface.
- Optimized HTTPS service stability and performance.
- Refined sample rate display formatting.
- Synchronized headphone plug/unplug status with Web UI data.
- Fixed an issue where remote controls from other devices could unintentionally trigger X8 operations.
1.0.0.26
- Added two extra customizable buttons for the remote control: Screen Off and Back
- Remote control Left/Right buttons and Pause button can now adjust soundstage width when not using Bluetooth input
- Added more startup volume options: -5 dB to -50 dB
- Added custom DIM level adjustment: -15 dB to -50 dB
- Added support for the new Web UI, applicable to future Web UI updates
- Fixed several letter capitalization inconsistencies
1.0.0.25
-
Fixed an issue in firmware 1.0.0.24 where the device may restart and reset after approximately one hour of use.
1.0.0.24
- Loudness threshold minimum adjustable down to -40 dB
- Added more options for startup volume
- Fixed occasional screen freezing issue
- Improved detection of some 5 GHz Wi-Fi networks
1.0.0.23
- Added a new “+” button to the HP-EQ section in the device UI
- Fixed spectrum display delay issue when using IIS input at 768kHz
- Fixed DSP not taking effect on startup when using IIS input at 768kHz
1.0.0.22
-
Fixed an issue that may occur during music playback via SPDIF
1.0.0.21
- Added a -12 dB option to Volume Passthrough Mode
- Added a negative adjustment range for VU meter sensitivity
- Refined mute behavior: volume now returns to the previous level when exiting mute via the knob
- Updated the default sleep setting to 10 minutes with no signal (in compliance with EU regulations)
- Fixed an issue where the IIS input could repeatedly switch between 44.1 kHz and 768 kHz
- Improved Wi-Fi connection stability
- Fixed a DoP playback distortion issue when using SPDIF input
1.0.0.20
- Fixed an issue introduced in firmware 1.0.0.19 where the volume adjustment in the Windows system was not working properly.
1.0.0.19
- Fixed an issue where playback could stop after a period of time when using the Optical/Coaxial input
- Fixed a bug related to the Loudness function
- Fixed an issue where the comma (,) could not be entered when typing the Wi-Fi password
- Added backup and restore functionality
- Added headphone amplifier power display to the voltage/current VU meters
- Optimized Wi-Fi connection stability
1.0.0.18
- Added feature: The power key can now be configured as an output switch.
- Bug fixes
1.0.0.17
Initial Release